Specificaties

Serial Interface
Serial PortsICS-2105AT 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485 ICS-2102T 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485 ICS-2102TS 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485
Serial StandardsRS232 / 4-wire RS422 or RS485 / 2-wire RS485
Baud Rate (Data Rate)50bps to 921Kbps
Data Bits5, 6, 7, 8
Parity Type1, 1.5, 2
Stop BitOdd, Even, None, Space, Mark
Flow ControlRTS/CTS and DTR/DSR (RS232 only) XON/XOFF
SignalsRS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS422: Tx+, Tx-, Rx+, Rx-, GND 4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND 2-wire RS485: Data A (+), Data B (-), GND

Toepassingen

  • Access Control System – Traditional System Application
  • Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-210xT series Serial Device Server, the access control machine is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-210xT series can be linked to an xDSL router to get the internet access capability so that the access control can be set and monitored over the internet.
  •  
  • Process Control
  • To monitor, configure and manage the robotic conveyer including other production machines, PLC (Programmable Logical Control) is required to drive the above manufacturing process. The ICS-210xT series can be set to the TCP Server mode and connected to the PLC.  Thus, the administrator can configure and set command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine.
  • Surveillance Motion Control – Pair Connection Mode
  • Using pair connection mode via the fiber optic patch cord, the ICS-210xT series can extend the distance of the deployed devices via RS232, RS422 and RS485 interfaces, making the remote management of these devices from the monitoring center easier and efficient.

Omschrijving

Watch out - this item is the Planet ICS-2102T below is the description for three different units.
The Planet ICS-2102T has a 100FX SC, MM/2km.

Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application

PLANET ICS-210xT Serial Device Server series is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking. So as to extend the network distance efficiently and inexpensively. There is one 100BASE-FX single-mode/multi-mode media available in the ICS-210xT series. It's operating temperature ranges from -40 to 75 degrees C for your network needs. The ICS-210xT series is a time-saving and cost-effective solution for users and system integrators. They can quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.

For the complete range of industrial products on shop4power click here: https://shop4power.nl/s/industrieel-ethernet/

 

 

Efficiently Extend Network Distance

The Planet ICS-2105AT especially equips one fiber interface (100BASE-FX, choice of fiber-connector from SC / LC, multi-mode / single-mode fiber). With this it is able to extend the distance of deploying serial equipment and hosts. Users are able to select fiber-optic cables (based on distance) provided for distance extension from 2 kilometers (via multi-mode fiber) to 60 kilometers (via single-mode fiber) or longer.

 

Remote Management 

As the ICS-210xT series provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently. It can be done via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes. These modes are for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection options are available for a large networking environment as well.

Stable Performance under Difficult Environments

The ICS-210xT series provides a high level of immunity against electromagnetic interference and heavy electrical surges. These are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-210xT series to be placed in almost any difficult environment.

The ICS-210xT series with compact IP30 standard metal case allows either DIN-rail or wall mounting for efficient use of cabinet space. The ICS-210xT series also provides an integrated power supply source. This source has a wide range of voltages (9 to 48V DC/24V AC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.

 

Dual Power Input for High Availability Network System

The Planet ICS-2105AT features a strong dual power input system. It has wide-ranging voltages (9V~48V DC/24V AC) incorporated into customer’s automation network. This to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically. This to keep powering the ICS-210xT series via Power Supply 2 without any break of operation.

 

Effective Alarm Alert for Better Protection

The ICS-210xT series comes with a Fault Alarm feature. This feature can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-210xT series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

For more information on Planet product, go to: http://planet.com.tw

Vragen

Wanneer wordt mijn bestelling verzonden?

Op een werkdag vóór 15:00 uur besteld, verzenden we dezelfde dag nog. Na 15:00 uur of in het weekend verzenden we de volgende werkdag.

Zijn de prijzen exclusief btw?

Ja. De winkelprijs is exclusief btw. U ziet ook het bedrag inclusief btw. De productgegevens voor zoekmachines gebruiken de prijs exclusief btw.

Kan ik een oud typenummer opzoeken?

Ja. Op de homepage zoekt u een Wetac- of Intercel-nummer. U komt bij de opvolger uit als die in de shop staat.

€ 109,00 excl. btw€ 131,89 incl. btw In winkelwagen